<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-28 04-41-35
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 60 dBuV SANDELS
Pilot RDS Phase Difference
4.6 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 69 kHz 13666 12,8275
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,7 dBr 5,36 dBr 5,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 69 kHz MIN: 11 kHz % above 76 kHz: 12,8275 Acquired: 2025/02/28 4.40.31 Total samples: 13666 Equivalent time: 0:11:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,8 dBr MIN: 4,7 dBr AVE: 5,36 dBr % above 12,2 dBr: 0,0 Last value: 5,7 dBr (2025/02/28 4.40.31) 04.26 04.28 04.30 04.32 04.34 04.36 04.38 04.40 0 2 4 6 Pm [dBr]